OUTPUT WATTAGE
600W
BEST SOLUTION FOR
Server ,Workstation ,PCs
DIMENSION
140x150x86(mm)
5.51x5.91x3.39(inch)
INPUT SPEC
VOLTAGE: 100~240 VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT: 10A/5A AT ANY LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT: 20/40 AMPS@115/230VAC
DC OUTPUT SPEC
Output Voltage |
Output Current Min. |
Output Current Max. |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
+5V |
0.5 |
25 |
±5% |
±50mV |
50mV |
+12V |
1 |
45 |
±5% |
±50mV |
120mV |
-12V |
0 |
0.8 |
±5% |
±50mV |
120mV |
+3.3V |
0.5 |
25 |
±5% |
±50mV |
50mV |
+5VSB |
0.1 |
3.5 |
±5% |
±50mV |
50mV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TOTAL POWER: 600W(MAX)
FEATURES
*TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE -20℃ ~ 80℃
*HOLD UP TIME: 16ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
*EFFICIENCY: TYPICAL 80~83% AT 25℃ 115V FULL LOAD
*POWER GOOD SIGNAL: ON DELAY 100ms TO 500ms, OFF DELAY 1ms
*OVER POWER PROTECTOIN
*OVER VOLTAGE PROTECTOIN
*SHORT CIRCUIT PROTECTION
*OVER CURRENT PROTECTION
*COOLING: ONE 80mm DC FAN
*ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D
*EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
*SAFETY: TO MEET UL, CUL, TUV, CCC
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.