OUTPUT WATTAGE
450W
BEST SOLUTION FOR
Server ,Workstation ,Storage System ,IPC
DIMENSION
185x150x86(mm)
7.28x5.91x3.39(inch)
INPUT SPEC
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 Hz
INPUT CURRENT: 7A/3A @ 115/230 VAC
INRUSH CURRENT: 25/50 AMPS @115/230 VAC
(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95%@115V AND 90%@230V, FULL LOAD, FOLLOWING THE STANDARD OF IEC61000-3-2 CLASS D
DC OUTPUT SPEC
Output Voltage |
Output Current Min. |
Output Current Max. |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
+5V |
1.0 |
25 |
±5% |
±1% |
50mV |
+12V |
1.0 |
37 |
±5% |
±1% |
120mV |
-12V |
0 |
0.5 |
±5% |
±1% |
120mV |
+3.3V |
1.0 |
20 |
±5% |
± 1% |
50mV |
+5VSB |
0.1 |
3 |
±5% |
±1% |
50mV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* +5V AND +3.3V MAX. POWER: 150W
* TOTAL POWER: 450W (MAX)
FEATURES
* TEMPERATURE RANGE : OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
* EFFICIENCY: THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 87.8%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING.
* OUTPUT PROTECTION: OPP / OVP / OCP / SCP
* HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
* BALANCE LOAD SHARING DESIGN
* REMOTE ON/OFF CONTROL
* LEAKAGE CURRENT: 3.5mA. RMS. MEASUREMENT WILL BE MADE AT 240VAC AND 60HZ
* ISOLATION: BUILT-IN IN THE POWER MODULE
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.