OUTPUT WATTAGE
320W
BEST SOLUTION FOR
Server ,Workstation ,Storage System ,IPC
DIMENSION
185x150x86(mm)
7.28x5.91x3.39(inch)
INPUT SPEC
VOLTAGE: 90 ~ 264 VAC FULL RANGE
DC OUTPUT SPEC
Output Voltage |
Output Current Min. |
Output Current Max. |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
5V |
3 |
25 |
± 5% |
± 1% |
50mV |
12V |
2 |
16 |
± 7% |
± 1% |
120mV |
-5V |
0 |
0.5 |
±10% |
± 1% |
150mV |
-12V |
0 |
0.5 |
±10% |
± 1% |
150mV |
3.3V |
1 |
18 |
± 5% |
± 1% |
50mV |
+5VSB |
0.1 |
2 |
± 5% |
± 1% |
60mV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
REMARKS: *TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 35 A *TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 302 W
FEATURES
*Active PFC (full range), MEET IEC-1000-3-2 CLASS D
*TEMPERATURE RANGE : OPERATING 0℃ ~ 40℃, STORAGE –20℃ ~ 70℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
*SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950
*HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
*Cooling: TWO 40 mm DC FANS (MODULE)
*AC INLET IN EACH MODULE, SINGLE AC INLET -- OPTIONAL
*Serial ATA optional
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.